Send Message
Beijing Silk Road Enterprise Management Services Co.,LTD
Email : jeffreyth@slurrypump.com TEL: 86-731-86187065
Home > Products > Water Source Heat Pump >
R410A Multifunction Geothermal Ground Source Heat Pump Water To Water Automaticlly Defrosting
  • R410A Multifunction Geothermal Ground Source Heat Pump Water To Water Automaticlly Defrosting
  • R410A Multifunction Geothermal Ground Source Heat Pump Water To Water Automaticlly Defrosting
  • R410A Multifunction Geothermal Ground Source Heat Pump Water To Water Automaticlly Defrosting

R410A Multifunction Geothermal Ground Source Heat Pump Water To Water Automaticlly Defrosting

Place of Origin Guangzhou China
Brand Name horizontal-slurrypump.com
Certification CE ISO CCC UKAS,ROHS
Model Number OEM
Document Product Brochure PDF
Product Details
Materail:
Galvanized Steel Sheet
Contactor:
Fuji Brand
Copper Pipe Thick:
1 Mm
Compressor:
ZW Series ,With Crank Heating
Working Temperature:
-20--45 Degree
Insulation:
Foam Pack Pipe And Stick On The Machine Innner
Defrosting:
Automaticlly
Temperature:
80 Degree
Highlight: 

geothermal heat pump

Payment & Shipping Terms
Minimum Order Quantity
5 PCS
Price
Negotiation
Packaging Details
Plywooden case
Delivery Time
15 days
Payment Terms
T/T, L/C WESTERN UNION
Supply Ability
800/MONTH
Product Description

R410A Multifunction geothermal ground source heat pump water to water

 

Technology Specification

 

Water source heat pump Sheet data 

 

MODEL Unit MDS15D
Rated heating capacity KW 5
Hot water supply L/h 100
Average heating input power KW 1.2
Rated heating input current A 6
Max outlet water temp 80
COP   4
Power V/Hz 220V/50
Noise Db(a) 50
Dimension W*D*H mm 657×557×765
Packing size W*D*H mm 737×637×915
Unit weight KG 75
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Panasonic
water source heat exchanger Type   Plate heat exchange
Pipe size DN 25
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 2000L/h
Water pressure down Kpa 30
Pipe size DN 25
Max house heating M2 40
MODEL Unit MDS20D
Rated heating capacity KW 7
Hot water supply L/h 150
Average heating input power KW 1.7
Rated heating input current A 9
Max outlet water temp 80
COP   4
Power V/Hz 220V/50
Noise Db(a) 50
Dimension W*D*H mm 657×557×765
Packing size W*D*H mm 737×637×915
Unit weight KG 75
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Panasonic
water source heat exchanger Type   Plate heat exchange
Pipe size DN 25
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 2000L/h
Water pressure down Kpa 30
Pipe size DN 25
Max house heating M2 55
MODEL Unit MDS30D
Rated heating capacity KW 12
Hot water supply L/h 260
Average heating input power KW 2.89
Rated heating input current A 13/6
Max outlet water temp 80
COP   4
Power V/Hz 220V/380V/50
Noise Db(a) 50
Dimension W*D*H mm 657×557×765
Packing size W*D*H mm 737×637×915
Unit weight KG 108
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Copeland
water source heat exchanger Type   Plate heat exchange
Pipe size DN 25
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 3300L/h
Water pressure down Kpa 35
Pipe size DN 25
Max house heating M2 100
MODEL Unit MDS40D
Rated heating capacity KW 16
Hot water supply L/h 380
Average heating input power KW 4
Rated heating input current A 9
Max outlet water temp 80
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 50
Dimension W*D*H mm 657×557×765
Packing size W*D*H mm 737×637×915
Unit weight KG 145
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Copeland
water source heat exchanger Type   Plate heat exchange
Pipe size DN 32
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 4000L/h
Water pressure down Kpa 40
Pipe size DN 25
Max house heating M2 125
MODEL Unit MDS50D
Rated heating capacity KW 19
Hot water supply L/h 400
Average heating input power KW 4.4
Rated heating input current A 9
Max outlet water temp 80
COP   4.2
Power V/Hz 380V/50
Noise Db(a) 50
Dimension W*D*H mm 657×557×765
Packing size W*D*H mm 737×637×915
Unit weight KG 145
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Copeland
water source heat exchanger Type   Plate heat exchange
Pipe size DN 32
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 5000L/h
Water pressure down Kpa 40
Pipe size DN 25
Max house heating M2 150
MODEL Unit MDS60D
Rated heating capacity KW 25
Hot water supply L/h 520
Average heating input power KW 6
Rated heating input current A 12
Max outlet water temp 80
COP   4.5
Power V/Hz 380V/50
Noise Db(a) 50
Dimension W*D*H mm 657×557×765
Packing size W*D*H mm 737×637×915
Unit weight KG 158
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Copeland
water source heat exchanger Type   Plate heat exchange
Pipe size DN 32
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 6000L/h
Water pressure down Kpa 45
Pipe size DN 25
Max house heating M2 175
Model Unit MDS100D
Rated heating capacity KW 38
Hot water supply L/h 800
Average heating input power KW 8.8
Rated heating input current A 18
Max outlet water temp 80
COP   4.6
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1050*810*760
Packing size W*D*H mm 1140*900*910
Unit weight KG 290
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Copeland
water source heat exchanger Type   Plate heat exchange
Pipe size DN 32
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 10000L/h
Water pressure down Kpa 50
Pipe size DN 32
Max house heating M2 300
Model Unit MDS150D
Rated heating capacity KW 42
Hot water supply L/h 1200
Average heating input power KW 11
Rated heating input current A 21
Max outlet water temp 80
COP   4.6
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1050*810*760
Packing size W*D*H mm 1140*900*910
Unit weight KG 300
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Copeland
water source heat exchanger Type   Plate heat exchange
Pipe size DN 32
Hot water side heat exchange Type   Coil heat exchanger
Water flow L/H 15000L/h
Water pressure down Kpa 50
Pipe size DN 32
Max house heating M2 350
MODEL Unit MDS200D
Rated heating capacity KW 74
Hot water supply L/h 1590
Average heating input power KW 17.6
Rated heating input current A 36
Max outlet water temp 80
COP   4.6
Power V/Hz 380V/50
Noise Db(a) 58
Dimension W*D*H mm 1260×850×860
Packing size W*D*H mm 1350×910×1020
Unit weight KG 630
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Copeland
water source heat exchanger Type   Plate heat exchange
Pipe size DN 63
Hot water side heat exchange Type   Coil heat exchanger
Water flow M3/H 20000L/h
Water pressure down Kpa 55
Pipe size DN 50
Max house heating M2 600
MODEL Unit MDS300D
Rated heating capacity KW 100
Hot water supply L/h 2400
Average heating input power KW 25
Rated heating input current A 45
Max outlet water temp 80
COP   4.6
Power V/Hz 380V/50
Noise Db(a) 55
Dimension W*D*H mm 1260×850×860
Packing size W*D*H mm 1350×910×1020
Unit weight KG 660
Refrigerant   R134A
Working air temp range (-40℃)—45℃
compressor Type   Copeland
water source heat exchanger Type   Tube heat exchange
Hot water side heat exchange Type   Coil heat exchanger
Water flow M3/H 30000L/h
Water pressure down Kpa 60
Pipe size DN 50
Max house heating M2 730

 

 

What is a Geothermal heat pumps:

 

Geothermal heat pumps systems are one of the most efficient, environmentally friendly ways to heat and

cool buildings because each unit responds specifically to the heating or cooling load of the individual zone it serves. These systems are ideal for office buildings, hotels, health care facilities, schools, condominiums and apartments.

The benefits are outstanding - excellent comfort, better efficiency and lower operating costs.

 

 

NEW ENERGY water source heat pump absorb heat(energy) from underground water and transfer it to warm and

heat the water to 60deg.C. The house could be warmed up by pumping the hot water to floor heating pipe or radiators. Cooling function is optional in the meantime.

 

 

Feature 

1. Copeland EVI scroll R407C compressor.

 

2. Designed for central heating for houses in cold area including North Europe and East Europe.

 

3. Can work stably at -25DegC ambient and the COP at -15DegC ambient is up to 2.5.

 

4. Can work with auxiliary heater.

 

5. Using electronic expansion valve, achieving accurate, stable and high efficiency throttling.

 

6. Split design, no water system outside, no freezing and damage to water system. Optional

refrigerant pipe quick connection is available, to reduce installation cost.

 

7. Low noise design for the outdoor unit. The compressor is on a floating plate to reduce vibration at the most extent. Noise insulation inside the cabinet. The fan is extremely quiet.

 

8. The refrigerant connections are designed to allow hiding all pipes, wires into the ground to ensure good looking installation.

 

R410A Multifunction Geothermal Ground Source Heat Pump Water To Water Automaticlly Defrosting 0

 

 

 

Packaging & Shipment

1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.

 

2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transportation

 

3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.

 

4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.

 

5>Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)

Packaging Details :Standard export packing -with plywood case packages,OEM is available for Factory price heat pump water heaters

Delivery Time :15 work days after arrival of down payment

 

 

CONTACT US AT ANY TIME

0086-17773109286
Floor 5, 2nd Building, Zhonglu Industrial Zone,Shenzhen City, Guangdong Province China (Mainland)
Send your inquiry directly to us