Swimming pool Parameters tables MDY10D-MDY300D
MODEL | Unit | MDY10D | |
Rated heating capacity | KW | 3.5 | |
Average heating input power | KW | 0.8 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×538 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1200L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY15D | |
Rated heating capacity | KW | 5.5 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×539 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1800L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY20D | |
Rated heating capacity | KW | 9 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 7 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 75 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 3500L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY30D | |
Rated heating capacity | KW | 14 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 35 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*790mm |
Packing size | W*D*H | mm | 1200*520*870mm |
Unit weight | KG | 110 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 5500L/h | |
Water pressure down | Kpa | 40 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY40D | |
Rated heating capacity | KW | 16 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 18/9 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1440 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 6500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY50D | |
Rated heating capacity | KW | 19 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 7500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY60D | |
Rated heating capacity | KW | 26 | |
Average heating input power | KW | 6 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 9000L/h | |
Water pressure down | Kpa | 48 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY100D | |
Rated heating capacity | KW | 42 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY150D | |
Rated heating capacity | KW | 50 | |
Rated Cooling capacity | KW | 37 | |
Average input power | KW | 11 | |
Rated input current | A | 24 | |
Max outlet water temp | C | 38 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 18000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY200D | |
Rated heating capacity | KW | 84 | |
Average heating input power | KW | 19 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 28000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY300D | |
Rated heating capacity | KW | 100 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 45000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 |
Swimming pool heat pump heating:
1. High efficiency & energy saving
2. Safe & Comfort
3. Convenient & widely to use
4. Swimming Pool Heat Pump heating:
Swimming Pool Heat Pump heating:
* Long operating life
Using the advanced titanium in PVC or Nickel – copper in PVC shell & tube heat exchangers, which can resist corrosion from chlorine in the water.
* Economical and high efficiency
Using the more efficient heat pump technology, compared to other ordinary hot water equipment (for example, combustion oil boiler, comb-ussion gas boiler and electrical boiler),it reduces operation cost by 65%~80%,moreover,it produces little pollution for environment.
* Innovative design, easy installation and replacement.
Mono block (single unit conclusion) design, the unit is remarkable compact and easy to install.
* Advanced control
It is extremely easy to control the swimming pump unit because of the built-in computer with its intelligent control and LCD display.
* Use safely
Swimming pool/bath/hotel heat pump water heater
Advantage feature
A: Pool: Length, width, depth.
B: Ambient temperature.
C: Water input and output temperature.
Easy to use, once set, always have hot/cool water
Life span is 12-15 years
1 years