Meeting 26kW Swimming pool heat pump heater horizontal equipment
Specifications Technology
Swimming pool heat pump heating:
1. High efficiency & energy saving
2. Safe & Comfort
3. Convenient & widely to use
4. Swimming Pool Heat Pump heating:
Product description
Commercial Swimming Pool Heat pump are specially designed and engineered for Commercial pool or spa water temperature control. The V-shape design condensers airflow direction and intelligent control system are let the units high efficiency and stable working performance.
The COP of this type heat pump could be as high as 5.4 at working condition of 20/15(DB/WB),which saves you at least 80% energy compared with traditional electric swimming pool heating equipments.
Suitable for large pools in hotel, public parks, schools, sport center, gyms, etc.
Swimming Pool Heat Pump heating:
* Long operating life
Using the advanced titanium in PVC or Nickel – copper in PVC shell & tube heat exchangers, which can resist corrosion from chlorine in the water.
* Economical and high efficiency
Using the more efficient heat pump technology, compared to other ordinary hot water equipment (for example, combustion oil boiler, comb-ussion gas boiler and electrical boiler),it reduces operation cost by 65%~80%,moreover,it produces little pollution for environment.
* Innovative design, easy installation and replacement.
Mono block (single unit conclusion) design, the unit is remarkable compact and easy to install.
* Advanced control
It is extremely easy to control the swimming pump unit because of the built-in computer with its intelligent control and LCD display.
* Use safely
Swimming pool heat pump parameters tables
MODEL | Unit | MDY10D | |
Rated heating capacity | KW | 3.5 | |
Average heating input power | KW | 0.8 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×538 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1200L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY15D | |
Rated heating capacity | KW | 5.5 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×539 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 70 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 1800L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY20D | |
Rated heating capacity | KW | 9 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 7 | |
Max outlet water temp | ℃ | 35 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1180*380*680 |
Unit weight | KG | 75 | |
Refrigerant | R417A/R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 3500L/h | |
Water pressure down | Kpa | 30 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY30D | |
Rated heating capacity | KW | 14 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 35 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*790mm |
Packing size | W*D*H | mm | 1200*520*870mm |
Unit weight | KG | 110 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 5500L/h | |
Water pressure down | Kpa | 40 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY40D | |
Rated heating capacity | KW | 16 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 18/9 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1440 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 6500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY50D | |
Rated heating capacity | KW | 19 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 7500L/h | |
Water pressure down | Kpa | 45 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY60D | |
Rated heating capacity | KW | 26 | |
Average heating input power | KW | 6 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1350 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 9000L/h | |
Water pressure down | Kpa | 48 | |
Pipe size(water connection) | DN | 50 | |
MODEL | Unit | MDY100D | |
Rated heating capacity | KW | 42 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | C | 35 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY150D | |
Rated heating capacity | KW | 50 | |
Rated Cooling capacity | KW | 37 | |
Average input power | KW | 11 | |
Rated input current | A | 24 | |
Max outlet water temp | C | 38 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*760*1190mm |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20C)—45C | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 18000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY200D | |
Rated heating capacity | KW | 84 | |
Average heating input power | KW | 19 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 28000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 | |
MODEL | Unit | MDY300D | |
Rated heating capacity | KW | 100 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 35 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 1990*980*2080 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R410A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Titanium heat exchanger | |
Water flow | L/H | 45000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size(water connection) | DN | 63 |
Packaging & Delivery
Packaging Details: export wooden packing
Delivery Time: 15-30 days
Our Services
1. After installation, our company will be responsible for problems caused by quality of production or raw material except the damageable spare parts of heat pump caused by incorrect man-made operation during the guarantee period.
2. Intelligent Controlling service system will be avoid the long distance of the after sale problem. Wherever are you, our engineer can be controlled your equipment, when some questions occur on the equipment. Just tell us what number will be shown on the screen, then the engineer will be solve the problem.
3. We accept OEM, ODM and customization.
4. 24*7 after sales service. You will get satisfied service.
5. We have More than 17years production and sales experience; Professional sales team.
Swimming pool/bath/hotel heat pump water heater
Advantage feature
A: Pool: Length, width, depth.
B: Ambient temperature.
C: Water input and output temperature.
Easy to use, once set, always have hot/cool water
Life span is 12-15 years
1 years
CONTACT US AT ANY TIME